當前位置:北京時代新天測控技術有限公司>>技術文章>>維氏硬度計硬度示值誤差
硬度 符號 | 硬度計示值誤差的大允許值(±%) | |||||||||||||||
50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | 600 | 700 | 800 | 900 | 1000 | 1500 | |
HV0.015 | 10 | | | | | | | | | | | | | | | |
HV0.2 | 8 | | | | | | | | | | | | | | | |
HV0.25 | 8 | 10 | | | | | | | | | | | | | | |
HV0.05 | 6 | 8 | 9 | 10 | | | | | | | | | | | | |
HV0.1 | 5 | 6 | 7 | 8 | 8 | 9 | 10 | 10 | 11 | | | | | | | |
HV0.2 | | 4 | | 6 | | 8 | | 9 | | 10 | 11 | 11 | 12 | 12 | | |
HV0.3 | | 4 | | 5 | | 6 | | 7 | | 8 | 9 | 10 | 10 | 11 | 11 | |
HV0.5 | | 3 | | 5 | | 5 | | 6 | | 6 | 7 | 7 | 8 | 8 | 9 | 11 |
HV1 | | 3 | | 4 | | 4 | | 4 | | 5 | 5 | 5 | 6 | 6 | 6 | 8 |
HV2 | | 3 | | 3 | | 3 | | 4 | | 4 | 4 | 4 | 4 | 5 | 5 | 6 |
HV3 | | 3 | | 3 | | 3 | | 3 | | 3 | 4 | 4 | 4 | 4 | 4 | 5 |
HV5 | | 3 | | 3 | | 3 | | 3 | | 3 | 3 | 3 | 3 | 3 | 4 | 4 |
HV10 | | 3 | | 3 | | 3 | | 3 | | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
注: 1. 當壓痕對角線小于0.020mm時,表中未給出值。 2. 對于中間值,其大允許誤差可由內插法求得。 3. 表中值是以0.001㎜或壓痕對角線平均值的2%為大誤差給出的,以較大者為準。 |